کنتاکتور مدار فرمان 110 ولت AC اشنایدر الکتریک با 3NO 2NC
کنتاکتور مدار فرمان 110 ولت AC
TeSys D control relay – 3 NO 2 NC – <= 690 V – 110 V AC standard coil
range | TeSys | |
---|---|---|
product name | TeSys CAD | |
product or component type | Control relay | |
device short name | CAD | |
contactor application | Control circuit |
utilisation category | AC-15 AC-14 DC-13 | |
---|---|---|
pole contact composition | 3 NO 2 NC | |
[Ue] rated operational voltage | <= 690 V AC 25…400 Hz | |
control circuit type | AC at 50/60 Hz | |
[Uc] control circuit voltage | 110 V AC 50/60 Hz | |
[Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947 | |
[Ith] conventional free air thermal current | 10 A (at 60 °C) | |
Irms rated making capacity | 140 A AC conforming to IEC 60947-5-1 250 A DC conforming to IEC 60947-5-1 | |
[Icw] rated short-time withstand current | 100 A – 1 s 120 A – 500 ms 140 A – 100 ms | |
associated fuse rating | 10 A gG conforming to IEC 60947-5-1 | |
[Ui] rated insulation voltage | 600 V UL certified 600 V CSA certified 690 V conforming to IEC 60947-5-1 | |
mounting support | Rail Plate | |
connections – terminals | Screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end Screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end Screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end Screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end Screw clamp terminals 1 cable(s) 1…4 mm²solid without cable end Screw clamp terminals 2 cable(s) 1…4 mm²solid without cable end | |
tightening torque | 1.2 N.m – on screw clamp terminals – with screwdriver Philips No 2 1.2 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm | |
control circuit voltage limits | 0.3…0.6 Uc -40…70 °C drop-out AC 50/60 Hz 0.3…0.6 Uc -40…70 °C drop-out AC 50/60 Hz 0.8…1.1 Uc -40…60 °C operational AC 50 Hz 0.8…1.1 Uc -40…60 °C operational AC 50 Hz 0.85…1.1 Uc -40…60 °C operational AC 60 Hz 0.85…1.1 Uc -40…60 °C operational AC 60 Hz 1…1.1 Uc 60…70 °C operational AC 50/60 Hz 1…1.1 Uc 60…70 °C operational AC 50/60 Hz | |
operating time | 12…22 ms coil energisation and NO closing 4…12 ms coil de-energisation and NO opening 4…19 ms coil energisation and NC opening 6…17 ms coil de-energisation and NC closing | |
mechanical durability | 30 Mcycles | |
maximum operating rate | 180 cyc/mn | |
inrush power in VA | 70 VA 50 Hz (at 20 °C) | |
hold-in power consumption in VA | 8 VA 50 Hz (at 20 °C) | |
minimum switching voltage | 17 V | |
minimum switching current | 5 mA | |
non-overlap time | 1.5 ms on energisation between NC and NO contact 1.5 ms on de-energisation between NC and NO contact | |
insulation resistance | > 10 MOhm | |
mechanical robustness | Shocks control relay open: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks control relay closed: 15 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations control relay open: 2 Gn, 5…300 Hz conforming to IEC 60068-2-6 Vibrations control relay closed: 4 Gn, 5…300 Hz conforming to IEC 60068-2-6 | |
height | 77 mm | |
width | 45 mm | |
depth | 84 mm | |
net weight | 0.58 kg |